SUMMARY
ZOOMLINE ZAP-CM series mixing plant is principally used in construction of roads project on small or medium scale. Mobile type asphalt mixing plant is basically designed for effortless assembling and disassembling for convenient moving from one project site to another often. Mobile asphalt mixing plant can greatly save the time and costs of installation.
STRUCTURE
Continuous asphalt mixing plant is mainly composed of cold aggregate supply system, drying drum, continuous mixer, burning system, dust collecting system, finished asphalt storage silo, bitumen supply system and control system.
Technical Parameters of Mobile Continuous Asphalt Mixing Plant
Items | ZAP-C(M)20 | ZAP-C(M)40 | ZAP-C(M)60 | ZAP-C(M)80 |
Plant Capacity | 20t/h | 40t/h | 60t/h | 80t/h |
Cold Aggregate Feeding System | ||||
Hopper capacity | 3x4m3 | 4x4m3 | 4 x 6.5m3 | 4 x 6.5m3 |
Belt capacity | 40t/h | 60t/h | 80t/h | 100t/h |
Drying System | ||||
Drying drum size | 1000x4500mm | 1200x5000mm | 1500x6500mm | 1500x6500mm |
Drying capacity | 15-25t/h | 40-50t/h | 60-70t/h | 80-100t/h |
Burner (oil) | 40-130kg/h | 70-300kg/h | 100-400kg/h | 60-600kg/h |
Fuel consumption (oil) | 6.5-7kg/t | 6.5-7kg/t | 6.5-7kg/t | 6.5-7kg/t |
Dust Collecting System | ||||
Exhaust Fan power | 5.5kw | 7.5kw | 30kw | 30kw |
Finished Asphalt Silo | 2m3 | 2.5m3 | 4.5m3 | 4.5m3 |
Asphalt Temperature | 130-160 ℃ | 130-160 ℃ | 130-160 ℃ | 130-160 ℃ |
Total Power | -27kw | -57kw | -92kw | -100kw |
Plant capacity is base on standard working condition as followings:
Atmospheric pressure | 760mmHg |
Ambient temperature | 20℃ |
Material passing 40mm mesh | 100% |
Material passing 3mm mesh | 40% |
Material passing 74µm | ≤7% |
Aggregate temperature at discharging end of drum dryer | 160℃ |
Density of aggregate | 1650kg/m3 |
Specific heat of aggregate | 0.21kcal/kg℃ |
Filler content | 5% |
Bitumen content | 5% |
Sand content | ≤40% |
Max.aggregate size | ≤40mm |
Average moisture of cold aggregates | ≤5% |
Diesel calorific value | ≥10500Kcal/kg |
Heavy oil calorific value | ≥9850Kcal/kg |
Nature gas calorific value | ≥8000Kcal/Nm3 |